Bobcat A770 U1182-00 Error Code
U1182-00 Error Code
Display CAN Error is the main cause of U1182-00 error.To solve U1182-00 locate and open the low-pressure valve, then attach the refrigerant to the valve and charge from there. Ensure you use the right refrigerant type and amount, as specified by a manufacturer. It is possible to overcharge the AC, so consider seeking help from a mechanic.
Tip For A770 Model
When the temperature is below -30 C (-20 F), hydrostatic oil must be warmed before starting. The hydrostatic system will not get enough oil at low temperatures and will be damaged. Park the machine in an area where the temperature will be above -18 C (0 F) if possible.